TurboCycler 2 thermal cycler is designed specifically to enhance PCR efficiency and accuracy. It is equipped with a 7” sensitive touchscreen and a friendly graphic user interface, which makes operation highly intuitive. With flexible ramp rate and gradient temperature control, TurboCycler 2 greatly increases PCR accurate optimization. The Wi-Fi function enables you to monitor the PCR run status anytime remotely with walk-away convenience.


SHARE

TurboCycler 2 thermal cycler is designed specifically to enhance PCR efficiency and accuracy. It is equipped with a 7” sensitive touchscreen and a friendly graphic user interface, which makes operation highly intuitive. With flexible ramp rate and gradient temperature control, TurboCycler 2 greatly increases PCR accurate optimization. The Wi-Fi function enables you to monitor the PCR run status anytime remotely with walk-away convenience.

Features and Benefits

Outstanding Performance

 

Flexible Ramp Rate Control

Flexible Ramp Rate Control

from 0.1 - 5.5 ℃/sec to meet the need for the CRISPR related assays .

Fully Adjustable Lid Temperature

Fully Adjustable Lid Temperature

can be set between 35 and 120 °C for virtually any type of experiment including NGS pre-treatment.

Gradient Optimization

Gradient Optimization

range from 1 to 30 °C enables optimal experimental conditions in a single PCR run.

 

Specifications

Sample Block

  • 96 Well, Gradient Block                                    Compatible with regular profile or low profile 0.2 ml PCR tube, strip, non-skirted, semi-skirted and full-skirted 96-well plate

Block Temperature

  • Block Temperature Range                                4.0 - 100 °C
  • Max. Heating Rate                                           5.5 °C/sec
  • Max. Cooling Rate                                           3.3 °C/sec
  • Temperature Accuracy                                     +/- 0.3 °C
  • Temperature Uniformity Across Block             +/- 0.3 °C
  • Adjustable Ramp Rate                                     0.1 - 5.5 °C/sec

Gradient Temperature

  • Gradient Direction                                           Horizontal across the block
  • Gradient Temperature Range                          30 - 100 °C
  • Gradient Temperature Difference                    Max. span 30 °C

Heater Lid

  • Temperature Setting Range                            35 - 120 °C or off
  • Temperature Accuracy                                   +/- 1.0 °C

Software

  • Portability of Protocols                                   Save and transfer to computer or TurboCycler 2 via USB flash drive
  • Stored Program No.                                       > 4000 sets
  • Registered User Folder No.                            100 sets
  • User Folder Password Protection                    Yes
  • Run Status Report                                           Yes, HTML output and transfer via USB flash drive
  • Real-time Temp. Profile Export                        Yes, CSV output and transfer via USB flash drive
  • Tools                                                                Tm calculator, Copy number convertor, Master mix preparation wizard

General

  • Display                                                             7” color LCD with capacitive touch panel
  • Data Port                                                         1 USB Type-A front port for USB flash drive
  • Heated Lid                                                       35 - 120 °C or off
  • Auto Restart after Power Outage                    Yes
  • Remote Monitoring via Wi-Fi                          Optional
  • Footprint Dimensions (H x W x D)                  225 mm x 245 mm x 415 mm
  • Weight                                                            9.5 kg
  • Power Supply                                                  AC 100-240 V, 50/60 Hz, 750 W
  • Certification                                                     CE, RoHS

* Specifications are subject to change without prior notice.